CONTREX CX-1200 User Manual
Page 349

C - 3
(Continued)
Appendix C: Parameter Summary Numeric Quick Reference (continued)
MP-20 Fb Posn
Feedback Position (MP-20) displays the present value of the Feedback Position in Engineering Units, as specified by
Pulses FI2 (CP-267) and EU FI2 (CP-268). The placement of the decimal point is the same as the placement of the decimal
point in EU FI2 (CP-268).
Minimum Value: 0
Maximum Value: 999999999
Units: EU
MP-21 FbJobSize
Follower Job Size (MP-21) displays the present value determined by the Follower Frequency and Follower Sync inputs.
Displayed in EU’s. It is the size of the very last job size that was encountered.
Minimum Value: 0
Maximum Value: 9999999
Units: EU
MP-22 FbJbSzVar
Follower Job Size Variance (MP-22) displays the maximum variance of the last 16 follower job sizes. Displayed in EU’s.
Minimum Value: -999999
Maximum Value: 999999
Units: EU
MP-23 FbJbSzAve
Follower Job Size Average (MP-23) displays a running average value of the last 16 follower job sizes determined by the
Follower Frequency and Follower Sync inputs. Displayed in EU’s.
Minimum Value: 0
Maximum Value: 9999999
Units: EU
MP-24 FbJbSzAct
Follower Job Size Active (MP-24) displays a running average value of the last 16 qualifying follower job sizes determined
by the Follower Frequency and Follower Sync inputs. Displayed in EU’s. This is the job size currently being used by the
control algorithm.
Minimum Value: 0
Maximum Value: 9999999
Units: EU
MP-25 FbNetOfst
Follower Net Offset (MP-25) displays the resultant Net-Offset applied to the follower position after considering the
FbSnsrDist (CP-350) and the FbSnsrOfst (CP-351) values. FbNetOfst (MP-25) is the final resultant offset inside a
follower job size.
Minimum Value: -9999999
Maximum Value: 9999999
Units: EU