Offsets & phase p2/2 – CONTREX CX-1200 User Manual
Page 117
5 - 24
OFFSETS & PHASE P2/2
Ld Posn
Lead Position (MP-10) displays the present value of the Lead Position in Engineering Units, as specified by Pulses FI1
(CP-262) and EU FI1 (CP-263). The placement of the decimal point is the same as the placement of the decimal point in
EU FI1 (CP-263).
LdSnsrDist
Lead Sensor Distance (CP-340) may be used to inform the CX-1200 of the distance from the critical contact point to the
Lead Sync sensor. Applied to the lead position only during sync pulse acceptance into the control algorithm.
LdSnsrOfst
Lead Sensor Offset (CP-341) may be used to set a distance offset to the lead position. This offset becomes effective
immediately upon entry. Values entered will rollover at a job size, or be resolved to be within a job size.
LdNetOfst
Lead Net Offset (MP-15) displays the resultant Net-Offset applied to the lead position after considering the LdSnsrDist
(CP-340) and the LdSnsrOfst (CP-341) values. LdNetOfst (MP-15) is the final resultant offset inside a lead job size.
Fb Posn
Feedback Position (MP-20) displays the present value of the Feedback Position in Engineering Units, as specified by
Pulses FI2 (CP-267) and EU FI2 (CP-268). The placement of the decimal point is the same as the placement of the
decimal point in EU FI2 (CP-268).
FbSnsrDist
Follower Sensor Distance (CP-350) may be used to inform the CX-1200 of the distance from the critical contact point to
the Follower Sync sensor. Applied to the follower position only during sync pulse acceptance into the control
algorithm.
FbSnsrOfst
Follower Sensor Offset (CP-351) may be used to set a distance offset to the follower position. This offset becomes
effective immediately upon entry. Values entered will rollover at a job size, or be resolved to be within a job size.
FbNetOfst
Follower Net Offset (MP-25) displays the resultant Net-Offset applied to the follower position after considering the
FbSnsrDist (CP-350) and the FbSnsrOfst (CP-351) values. FbNetOfst (MP-25) is the final resultant offset inside a
follower job size.
NonSyncPhase
Non-Sync Phase (CP-357) may be used to set a distance offset to the non-sync follower position. This phase offset
becomes effective immediately upon entry.
SyncFlgDif
Sync Flag Difference (MP-29) displays the difference, in Follower EU’s, between the position of the Lead and Follower
sync pulses.