FUNCTION (04) CONTROL COMMAND SEND
Table 24 Host Transmission
Character #
DESC
ASCII
STX
Address
Separator
Command
Inquiry
ETX
1
2
3
4
5
6
^B
0-99
,
ASCII2 Command String
?
^C
List of Valid ASCII2 Command Strings:
FST!
=
F-Stop
ULD!
=
Unload
HST!
=
H-Stop
RUN!
=
Run
LDD!
=
Load
PUD!
=
Set Unwind Diameter to Preset value
PWD! =
Set Wind Diameter to Preset value
PUC!
=
Set Unwind Roll Content to Preset value
PWC! =
Set Wind Roll Content to Preset value
PAU!
=
Set Unwind Diameter and Roll Content to Preset values
PAW!
=
Set Wind Diameter and Roll Content to Preset values
RAP!
=
Set Both Wind and Unwind Diameter and Roll Content to Preset values
NSR!
=
Negate the Line Speed Scaled Reference
OLW! =
Open Loop Wind
FWI!
=
Freeze the Wind Integral
STR!
=
Stop the Line Speed Ramp
OLU!
=
Open Loop Unwind
FUI!
=
Freeze the Unwind Integral
Command Field
Insert any of the valid ASCII2 command strings defined above.
Inquiry Field (Inquiry)
The inclusion of the inquiry designator is optional. If no response is required this character may be
omitted from the message. If this character field is not included in the message, the commanded
operation will be performed, however the control will not respond.
Table 25 CX-1200 Response
Character #
DESC
ASCII
1
2
3
4
5
STX
Msg Error
Separator
Command
ETX
^B
0-FF
,
^C
Command Field
If the requested command is acted upon, this field will contain the command string that was sent. If
an error occurred, this field will contain an “E” followed immediately by an ASCII representation of