CONTREX CX-1200 User Manual
Page 378

C - 32
(Continued)
Appendix C: Parameter Summary Numeric Quick Reference (continued)
MP-154 Norm Pwr Ups
Normal Power Ups (MP-154) displays the number of normal power-ups since the most recent “Clear-7” power-up . This
value is reset only by a “Clear-7” power-up. Norm Pwr Ups (MP-154) is used primarily for troubleshooting.
Minimum Value: 1
Maximum Value: 65535
Units: Counts
MP-155 Low Pwr Cntr
Low Power Counter (MP-155) displays the number of low power detections, including normal “Power Downs”. You can
reset this numeric value, but only in Clr Fault Cntrs (CP-491). Low Pwr Cntr (MP-155) is used primarily for
troubleshooting.
Minimum Value: 0
Maximum Value: 65535
Units: Counts
MP-156 Mem Err Cntr
Memory Error Counter (MP-156) displays the number of memory test failures that occurred during “Power Up”. You can
reset this numeric value, but only in Clr Fault Cntrs (CP-491). Mem Err Cntr (MP-156) is used primarily for
troubleshooting.
Minimum Value: 0
Maximum Value: 65535
Units: Counts
MP-157 WatchDogCntr
Watch Dog Counter (MP-157) displays the number of watch dog resets that were caused by watchdog time-out.
WatchDogCntr (MP-157) is used primarily for troubleshooting. You can reset this numeric value, but only in Clr Fault
Cntrs (CP-491).
Minimum Value: 0
Maximum Value: 65535
Units: Counts
MP-158 MiscIntrptCntr
Miscellaneous Interrupt Counter (MP-158) displays the number of miscellaneous interrupts that occurred as the result of
bus errors, address errors, divide-by-0 errors, unexecuted instruction errors, general exceptions, and unexecuted and
spurious interrupts. You can reset this numeric value, but only in Clr Fault Cntrs (CP-491). MiscIntrptCntr (MP-158) is
used primarily for troubleshooting.
Minimum Value: 0
Maximum Value: 65535
Units: Counts