CONTREX CX-1200 User Manual
Page 398

C - 52
(Continued)
Appendix C: Parameter Summary Numeric Quick Reference (continued)
resolving the position error to zero, upon entry into RUN state when in non-Sync follower mode.
1 = Enabled (position error will be recovered)
0 = OFF = Disabled (default)
Minimum Value: 0
Maximum Value: 1
Default Value: 0
Units: Coded
CP-350 FbSnsrDist
Follower Sensor Distance (CP-350) may be used to inform the CX-1200 of the distance from the critical contact point to
the Follower Sync sensor. Applied to the follower position only during sync pulse acceptance into the control
algorithm.
Minimum Value: -999999
Maximum Value: 9999999
Default Value: 0
Units: EU
CP-351 FbSnsrOfst
Follower Sensor Offset (CP-351) may be used to set a distance offset to the follower position. This offset becomes
effective immediately upon entry. Values entered will rollover at a job size, or be resolved to be within a job size.
Minimum Value: -999999
Maximum Value: 9999999
Default Value: 0.00
Units: EU
CP-356 PhaseSource
Phase Source (CP-356) identifies the source of the Non-Sync Phase, which may be used to set a distance offset to the
non-sync follower position. Phase Sources are:
3 = Analog Input 2
2 = Analog Input 1
1 = NonSyncPhase (CP-357) (default)
Minimum Value: 1
Maximum Value: 3
Default Value: 1
Units: Coded
CP-357 NonSyncPhase
Non-Sync Phase (CP-357) may be used to set a distance offset to the non-sync follower position. This phase offset
becomes effective immediately upon entry.
Minimum Value: -999999
Maximum Value: 9999999
Default Value: 0.00
Units: EU