beautypg.com

CONTREX CX-1200 User Manual

Page 398

background image

C - 52

(Continued)

Appendix C: Parameter Summary Numeric Quick Reference (continued)

resolving the position error to zero, upon entry into RUN state when in non-Sync follower mode.

1 = Enabled (position error will be recovered)
0 = OFF = Disabled (default)

Minimum Value: 0

Maximum Value: 1

Default Value: 0

Units: Coded

CP-350 FbSnsrDist

Follower Sensor Distance (CP-350) may be used to inform the CX-1200 of the distance from the critical contact point to
the Follower Sync sensor. Applied to the follower position only during sync pulse acceptance into the control
algorithm.

Minimum Value: -999999

Maximum Value: 9999999

Default Value: 0

Units: EU

CP-351 FbSnsrOfst

Follower Sensor Offset (CP-351) may be used to set a distance offset to the follower position. This offset becomes
effective immediately upon entry. Values entered will rollover at a job size, or be resolved to be within a job size.

Minimum Value: -999999

Maximum Value: 9999999

Default Value: 0.00

Units: EU

CP-356 PhaseSource

Phase Source (CP-356) identifies the source of the Non-Sync Phase, which may be used to set a distance offset to the
non-sync follower position. Phase Sources are:

3 = Analog Input 2
2 = Analog Input 1
1 = NonSyncPhase (CP-357) (default)

Minimum Value: 1

Maximum Value: 3

Default Value: 1

Units: Coded

CP-357 NonSyncPhase

Non-Sync Phase (CP-357) may be used to set a distance offset to the non-sync follower position. This phase offset
becomes effective immediately upon entry.

Minimum Value: -999999

Maximum Value: 9999999

Default Value: 0.00

Units: EU