Appendix C: Parameter Summary Numeric Quick Reference (continued)
of EU for point A that corresponds to the reference value that is entered in AI1 RA (CP-281).
Minimum Value: -9999999
Maximum Value: 9999999
Default Value: 0.0
Units: EU
CP-283 AI1 RB
Analog Input 1 Reference B (CP-283) is used to scale the Auxiliary Board Analog Input 1 in EU. Enter the value for
reference point B that corresponds to the EU's that are entered in EU@AI1 RB (CP-284).
Minimum Value: -15.0
Maximum Value: 25
Default Value: 10.0
Units: Volts or milliampere
CP-284 EU@AI1 RB
EU@Analog Input 1 Reference B (CP-284) is used to scale the Auxiliary Board Analg Input 1 in EU. Enter the number of
EU’s for point A that corresponds to the reference value that is entered in AI1 RB (CP-283).
Minimum Value: -9999999
Maximum Value: 9999999
Default Value: 100.0
Units: EU
CP-285 AI2 Mode
Analog Input 2 Mode (CP-285) identifies the mode of operation and the calibration that are used for the Auxiliary Board
Analog Input 2 signal.
2=Current
1=Voltage (default)
Minimum Value: 1
Maximum Value: 2
Default Value: 1
Units: Coded
CP-286 AI2 RA
Analog Input 2 Reference A (CP-286) is used to scale the Auxiliary Board Analog Input 2 in EU. Enter the Analog Input
2 signal value for reference point A that corresponds to the EU that are entered in EU@AI2 RA (CP-287).
Minimum Value: -15.0
Maximum Value: 25
Default Value: 0.0
Units: Volts or milliamperes
CP-287 EU@AI2 RA
EU @ Analog Input 2 Reference A (CP-287) is used to scale the Auxiliary Board Analog Input 2 in EU. Enter the number
of EU’s for point A that corresponds to the reference value that is entered in AI2 RA (CP-286).
Minimum Value: -9999999
Maximum Value: 9999999
Default Value: 0.0
Units: EU
CP-288 AI2 RB