C - 12
(Continued)
Appendix C: Parameter Summary Numeric Quick Reference (continued)
MP-100 DI 7..0
Digital Input 7..0 (MP-100) displays the value of the “J6” digital inputs. A ‘1’ in the bit location (see graphic below)
indicates a “low voltage” condition on the corresponding input (which is consistent with a contact closure to common).
F-Stop
R-Stop
H-Stop
Run
Jog Fwd
Jog Rvs
Keypad Lockout
Spare
Minimum Value: 00000000
Maximum Value: 11111111
Units: Coded
MP-101 DI 15..8
Digital Input 15..8 (MP-101) displays the value of the “J7” digital inputs. A ‘1’ in the bit location (see graphic below)
indicates a “low voltage” condition on the corresponding input (which is consistent with a contact closure to common).
These eight Inputs can be set up in the PLC Programming screen to generate a One-Shot-Pulse on a high-to-low
transition.
Batch Reset
Position Reset
Re-Learn
Phase Advance
Phase Retard
Block Select A
Sync Disable
Open Loop
Minimum Value: 00000000
Maximum Value: 11111111
Units: Coded