STD SIGNAL TESTS / FREQUENCY INPUTS P1/2
The STD Signals Tests / Frequency Inputs screen (page 1) displays the Monitor Parameters that are
associated with FI1 Frequency Input and the FI2 Frequency Input. Input a known frequency and monitor
the results here.
FI1 Hz
Frequency Input 1 Hertz (MP-01) displays the current frequency of the Frequency Input 1, in Hertz.
FI1 RPM
Frequency Input 1 RPM (MP-02) displays the current speed of the Frequency Input 1 encoder in RPM, based on PPR
FI1 (CP-261).
FI1 EU/Tm
Frequency Input 1 Engineering Units per Time (MP-05) displays the current speed of the Frequency Input 1 in the
Engineering Units per Time (EU/Tm) relative to the Pulses FI1 (CP-262), EU FI1 (CP-263) and Time Base (CP-209). The
placement of the decimal point is the same as the placement of the decimal point in EU FI1 (CP-263).
FI2 Hz
Frequency Input 2 Hz (MP-03) displays the current frequency of the Frequency Input 2, in Hertz.
FI2 RPM
Frequency Input 2 RPM (MP-04) displays the current speed of the Frequency Input 2 encoder in RPM, based on PPR
FI2 (CP-266).
FI2 EU/Tm
Frequency Input 2 Engineering Units per Time (MP-06) displays the current speed of the Frequency Input 2 in the
Engineering Units per Time (EU/Tm) relative to the Pulses FI2 (CP-267), EU FI2 (CP-268) and Time Base (CP-209). The
placement of the decimal point is the same as the placement of the decimal point in EU FI2 (CP-268).