CONTREX CX-1200 User Manual
Page 396

C - 50
(Continued)
Appendix C: Parameter Summary Numeric Quick Reference (continued)
The Maximum Speed Limit (CP-330) is the maximum positive and negative limit applied to the ScaledRef (MP-30) while
operating in “Run” mode.
Minimum Value: 0
Maximum Value: 9999999
Default Value: 5000
Units: EU/Tm
CP-331 Min Spd Lmt
The Minimum Speed Limit (CP-331) is the minimum positive and negative limit applied to the ScaledRef (MP-30) while
operating in “Run” mode. The ramp accelerates to the Min Spd Lmt (CP-331) if the reference speed is less than the
Min Spd Lmt (CP-331).
Minimum Value: 0
Maximum Value: 9999999
Default Value: 0
Units: EU/Tm
CP-332 Zero Speed
When the magnitude of the Fb EU/Tm (MP-06) is less than or equal to Zero Speed (CP-332), the Fb @ 0Spd bit (54) in
the PLC is set to “1”. This value, as well as the PLC Fb @ 0Spd bit condition, is used in other transparent internal
calculations that are based on feedback information.
Minimum Value: 0
Maximum Value: 100000
Default Value: 5.00
Units: EU/Tm
CP-333 Trim Authority
The trim contribution to the DAC output is limited to positive and negative Trim Authority (CP-333).
Minimum Value: 1
Maximum Value: 100
Default Value: 100.0
Units: Percent
CP-334 Integral Limit
The integral contribution to the trim term is limited to the positive and negative Integral Limit (CP-334). Integral Limit
(CP-334) can decrease the effects of integral windup or it can limit the maximum effect of the integral term.
Minimum Value: 1
Maximum Value: 100
Default Value: 100.0
Units: Percent
CP-335 LdSyncBand
Lead Sync Band (CP-335) sets a “dead-band” around the sync-mark position to allow for irregular sync marks. If the
actual sync pulse occurs inside this “dead-band”, the CX-1200 will presume an “in-sync” status, and therefore make no
sync-correction. A sync correction will be made if the sync pulse occurs outside this band. The band is defined as ±
the value entered.
Minimum Value: 0
Maximum Value: 9999999
Default Value: 0.0
Units: EU
CP-336 FbSyncBand