CONTREX CX-1200 User Manual
Page 379
![background image](/manuals/334431/379/background.png)
C - 33
(Continued)
Appendix C: Parameter Summary Numeric Quick Reference (continued)
MP-160 AI1 Bits
Analog Input 1 Bits (MP-160) displays the present value in ADC bits of Auxiliary Board Analog Input 1 signal.
Minimum Value: -8192
Maximum Value: 8192
Units: Bits
MP-161 AI1 Signal
Analog Input 1 Signal (MP-161) displays the present value of the Auxiliary Board Analog Input 1 signal in either volts
or milliamps relative to which setting (volts or current) has been entered in AI1 Mode (CP-280).
Minimum Value: -12.00
Maximum Value: 20
Units: Volt or Milliamps
MP-162 AI1 EU
Analog Input 1 EU (MP-162) displays the present value of the Auxiliary Board Analog Input 1 signal in Engineering
Units (EU) as relative to the AI1 RA (CP-281), EU@AI1 RA (CP-282), AI1 RB (CP-283) and EU@AI1 RB (CP-284). The
placement of the decimal point is the same as the placement of the decimal point in EU@AI1 RA (CP-282).
Minimum Value: -999999
Maximum Value: 999999
Units: EU
MP-163 AI2 Bits
Analog Input 2 Bits (MP-163) displays the present value in ADC bits of Auxiliary Board Analog Input 2 signal.
Minimum Value: -8192
Maximum Value: 8191
Units: Bits
MP-164 AI2 Signal
Analog Input 2 Signal (MP-164) displays the present value of the Auxiliary Board Analog Input 2 signal in either volts
or milliamps, relative to which setting (volts or current) has been entered in AI2 Mode (CP-285).
Minimum Value: -12.00
Maximum Value: 20
Units: Volt or Milliamps
MP-165 AI2 EU
Analog Input 2 EU (MP-165) displays the present value of the Auxiliary Board Analog Input 2 signal in Engineering
Units (EU) relative to the AI2 RA (CP-286), EU@AI2 RA (CP-287), AI2 RB (CP-288) and EU@AI2 RB (CP-289). The
placement of the decimal point is the same as the placement of the decimal point in EU@AI2 RA (CP-286).
Minimum Value: -999999
Maximum Value: 999999
Units: EU