DEMONSTRATION
MILLPWR
®
Operation Manual
4-14
•
Highlight the “Number” field in tool retract then enter a value of 3.
•
Press the
USE
key.
•
Press the “down” arrow key again, then enter 5 for
the number of holes.
•
In the “Dwell” field, enter 5 seconds as the length of time needed
for the quill to pause during the retract cycle.
In this example, the starting and ending angles were not changed. As a result, your first hole will
be placed at zero degrees. If you were to look at the face of a clock, zero degrees will be at
3 o’clock. Without a specified ending angle
MILLPWR
will space the number of holes entered
evenly around a full circle. If a counter-clockwise direction was applied to the hole pattern, the
second hole of our five hole pattern will be between 12 o’clock and 1 o’clock. The holes contin-
ue around the circle as shown below.