Troubleshooting guide – ACU-RITE MILLPWR 3 Axes User Manual
Page 234

TROUBLESHOOTING GUIDE
MILLPWR
®
Operation Manual
9-9
Poor finish
Check that the proper dimen-
sions were entered for each
step of your program.
Check that the correct tool
information was entered for
each step of the program.
Measure the tool diameter to
check for tool wear.
Check that the correct scale
factor is being used.
Symptom
Recommended
Corrective Action
Probable Cause
Incorrect dimensions
System is out of tune.
Perform the auto tuning pro-
cedures for all three axes.
If auto tuning your system
does not correct the problem,
contact your ACU-RITE dis-
tributor.
Dull tool
Incorrect feed rates and/or
spindle speeds
Gibs are worn or are out of
adjustment.
Replace or sharpen the tool.
Check that the correct feed
rates have been entered for
each step of your program.
Check your spindle speed
setting.
Refer to the machine tool
operation manual.