beautypg.com

Setup, Operation manual – ACU-RITE MILLPWR 3 Axes User Manual

Page 213

background image

SETUP

MILLPWR

®

Operation Manual

7-33

MILLPWR

includes two circle interpolation tests. The small circle test checks for machine-

related problems—an unbalanced ballscrew or poor gib adjustment, for example. The large
circle test checks whether or not the motors are in tune.

The circle should maintain its original shape (fluctuations up to 0.0005” are normal). If
fluctuations exceed 0.0005”, the system may require adjustment (refer to the Trouble-
shooting Guide
for recommended solutions). The examples on the next page illustrate
some of the problems that can be detected. For accurate results, do not run the circle test
while the spindle is under a cutting load.

You have the option of saving the test results onto a 3

1

/

2

” floppy disk for later review.

Circle Interpolation Test

To run the circle interpolation test:

From the Diagnostics screen, highlight “Circle Interpolation Test” and press

ENTER

.

Check that the table has at least 3

1

/

2

” of clearance for each axes.

Press either the

SMALL CIRCLE TEST

or

LARGE CIRCLE TEST

softkey.

(Optional) When the test is completed, insert a 3

1

/

2

” floppy disk into the

MILLPWR

disk

drive and press the

SAVE TO FLOPPY

softkey. After

MILLPWR

has finished saving,

remove the disk.

Press the

EXIT TEST

softkey

to close the “Circle Inter-
polation Test” screen.

Continue with Diagnostics or
press the

USE NEW SETTINGS

softkey.