13. The control will cause the axis to begin moving back and forth approxi-
mately two (2) inches in each direction.
14. While the axis is moving, the control automatically adjusts the Gain value until
the “Following Error” is at its lowest value.
15. Once the control has reach the optimal Gain value, it will automatically stop
axis motion and indicate it is done by displaying “Test Completed.”
16. The correct values for the Gain and Balance tests have now been established.
Now you will need to exit and save the new values in to the console.
17. Press the
STOP TEST
soft key, then press the
USE NEW SETTINGS
soft key.
18. Power down the console and restart to begin normal operation and have the
updated values implemented.