Programming, Operation manual – ACU-RITE MILLPWR 3 Axes User Manual
Page 45

PROGRAMMING
MILLPWR
®
Operation Manual
3-9
Using an electronic edge finder:
•
From the DRO screen, press the
SKEW
softkey.
•
Touch off on two or more points along any single straight edge of your part. You’ll
notice that the “Points” and “Angle” change as you enter points.
•
Press
USE
to accept all of the points and return to the DRO screen. Press
CANCEL
to
return to the DRO screen without accepting any points or affecting your previous
skew angle.
The
CLEAR ANGLE
softkey will reset the number of points and the skew angle to zero.
Using teach position:
•
From the DRO screen, press the
SKEW
softkey.
•
Move the table so that a mechanical indicator rests against any straight edge on the
part. Press the
TEACH POSITION
softkey to enter your coordinate.You’ll notice that the
“Points” change.
•
Now move the table so that the mechanical indicator touches another point on the same
straight edge. Press the
TEACH POSITION
softkey. You’ll notice that the “Points” and
“Angle” change.
Repeat this process for any additional points.
•
Press
USE
to accept all of the points and return to the DRO screen. Press
CANCEL
to
return to the previous screen without affecting your previous skew angle.
The
CLEAR ANGLE
softkey will reset the number of points and the angle to zero.