Setup, Operation manual – ACU-RITE MILLPWR 3 Axes User Manual
Page 212
SETUP
MILLPWR
®
Operation Manual
7-32
The table stop test shows whether or not an emergency stop (E-stop) condition has been
detected or the internal switch has been pressed.
Table Stop Test
Reports on whether or not the system detects an emergency stop
condition. An E-stop condition can originate from the operator
console, Z-axis, or optional AMI.
Displays the status of the table stop button (Pressed or Released)
on the operator console.
E-stop Signal
Status
Table Stop
Button
To display the table stop test:
•
From the Diagnostics screen, highlight "Table
Stop Test" and press
ENTER
. The test will run
automatically.
•
When the test is complete, press the
EXIT TEST
softkey to close the “Table Stop Test” screen.
•
Continue with Diagnostics or press the
USE NEW
SETTINGS
softkey.
Z-Limit
If Z-axis control is enabled, a “Fault” or “No Fault” message will
appear. A fault indicates that at least one of the limit switches on
the spindle has been disengaged.