beautypg.com

Analyzer add – 3Com 3500 User Manual

Page 758

background image

758

C

HAPTER

24: R

OVING

A

NALYSIS

3500

9000

9400

3900

9300

analyzer add

Defines a bridge port to serve as a dedicated analyzer port.

Valid Minimum Abbreviation

an a

Important Considerations

On CoreBuilder

®

3500 and CoreBuilder 9000 systems, you can

connect as many as 16 network analyzers to a system. On other
platforms, you can connect one network analyzer. For more accurate
analysis, attach the analyzer to a dedicated port instead of through a
repeater.

After a port is selected to serve as an analyzer port, it cannot receive
or transmit any other data. Instead, it receives only the data from the
ports to be monitored. If you have enabled the Spanning Tree Protocol
(STP) on the port, STP is automatically disabled.

If the physical port configuration changes in the system (that is, if you
remove or rearrange modules), the MAC address of the analyzer port
remains fixed. If you replace the module with the analyzer port with a
module of a different media type, the roving analysis port (RAP)
configuration for that port is cleared.

When you configure a port that is part of a virtual LAN (VLAN) as an
analyzer port, a warning is displayed because adding the port removes
the port from all VLANs. When the port is restored (when you remove
the analyzer port), it becomes a member of the default VLAN.

If the probe is attached to a 10 Mbps Ethernet analyzer port and the
roving analysis port (RAP) is monitoring a 100 Mbps Ethernet port
with a sustained traffic rate greater than 10 Mbps, the analyzer may
not see all of the frames.

After you enter a bridge port number, the system displays the MAC
address of the analyzer port. Record this information for setting up the
port that you want to monitor.

On the CoreBuilder 9000, the port to which the analyzer is attached
and the port you wish to monitor must be on the same blade.

Trunked ports and resilient link ports can not be configured as analyzer
ports.