beautypg.com

Module display – 3Com 3500 User Manual

Page 129

background image

module display

129

3500

9000

9400

3900
9300

module display

Generates software and hardware revision numbers, module status
information, and warning messages for certain module conditions.

Valid Minimum Abbreviation

mo d

Important Considerations

The module display provides the configuration information for the
module to which you are currently connected. To display configuration
information for another module, disconnect from the current module
through the Enterprise Management Engine (EME) and then connect
to the module that you want to display.

After you have logged in to the EME, you can access the module that
you want to manage.

Diagnostic messages appear in the display only if a module fails any of
the tests at start-up.

Fields in the Module Display

Field

Description

24 port Gigabit
Switching Fabric

32-character alphanumeric name that uniquely identifies
this module

3C number

Each module’s 3Com 3C product identification number

Built

Date and time when this software version was built

Diagnostics

Whether a module has passed or failed diagnostics.
Additional diagnostic messages describe a failure.

Memory size (AP, FP,
Flash, Buffer)

Memory capacities of the processors

Module ID

ID number that the system assigns to that module

Rev

Unique number assigned to the hardware build by 3Com

Serial

Each module’s unique serial number

Slot

Location of the module in the chassis (slot.subslot)

System name

Name of the system

System up time

Time that this module has been up and running

Time in service

Total operational time since the module was
manufactured

Version

Software release number