WAN Modules
Page 3-27
WSX-S-2W
The
WSX-S-2W
supports two (2) serial ports, which can provide access rates from 9.6 Kbps to
2 Mbps. The
WSX-S-2W
also supports three types of clocking (internal, external, and split). See
WSX-S-2W Technical Specifications on page 3-27 for more information.
♦ Note ♦
The
WSX-S-2W
does not support hardware compres-
sion.
The
WSX-S-2W
can sense and auto-configure for any of five serial cable types (
RS-232
,
V.35
,
X.21
,
RS-530
, and
RS-449
). A
WSX-S-2W
port is normally considered a physical
DTE
device. It
can be turned into a physical
DCE
device—for speed or clocking purposes— by plugging in a
DCE
cable. The
WSX-S-2W
senses whether a
DCE
or
DTE
cable is connected.
Software in the switch allows you to configure parameters for the Frame Relay or Point-to-
Point Protocol (
PPP
). Software commands allow you to view the status of the
WAN
connec-
tion at the
WSX-S-2W
board, port, or virtual circuit level. Extensive statistics are provided at
each level. Software commands for Frame Relay are described in Chapter 29, “Managing
Frame Relay”; commands for
PPP
are described in Chapter 30, “Point to Point Protocol.”
With the optional
HRE-X
you can increase routing performance to 1.5 million packets per
second per module and up to 12 Mpps in a fully-loaded 9-slot chassis.
WSX-S-2W Technical Specifications
Number of ports
2
Connector Type
High-density 26-pin shielded serial
Protocols Supported
Frame Relay and Point-to-Point (PPP)
Data Rates Supported
9.6, 19.2, 56, 64, 128, 256, 512,
768, 1024, 1536, 2048 Kbps
Clocking
Internal, External, or Split
Virtual Circuits Supported
Permanent Virtual Circuits (PVCs)
MAC Addresses Supported
4,096
Connections Supported
Physical Data Terminal Equipment (DTE) or
Data Communication Equipment (DCE)
Cable Supported
DTE or DCE in the following types:
R2-232, V.35, X.21, RS-530, RS-449
Power Consumption
5.25 amps (without an HRE-X)
6.75 amps (with an HRE-X)