Remote Network Monitoring (RMON)
Page 14-5
Time
Time since the last change in status.
System Resources
Amount of memory that has been allocated to this probe.
To see the detail for each of the probes enter the
probes
command followed by the entry
number as shown below.
/Networking % probes 1
RMON Probe Summary
Entry Slot/Port
Flavor
Status
Time
System Resources
1
2/
1
Ethernet
Active
0 hrs 39 mins
312 bytes
Probe’s Owner: Omni Switch/Router Ethernet probe on slot 2 port 1
/Networking % probes 2
RMON Probe Summary
Entry Slot/Port
Flavor
Status
Time
System Resources
2
2/
1
History
Active
0 hrs
4 mins
3656 bytes
Probe’s Owner: andy
History Control Buckets Requested
=
60
History Control Buckets Granted
=
60
History Control Interval
=
60 seconds
History Sample Index
=
6
/Networking % probes 3
RMON Probe Summary
Entry Slot/Port
Flavor
Status
Time
System Resources
3
2/
1
Alarm
Active
0 hrs
0 mins
1336 bytes
Probe’s Owner: andy
Alarm Rising Threshold
=
3000
Alarm Falling Threshold
=
3000
Alarm Rising Event Index
=
1
Alarm Falling Event Index
=
3
Alarm Interval
=
30 seconds
Alarm Sample Type
=
delta value
Alarm Startup Alarm
=
rising or falling alarm
Alarm Variable
=
ethernet octets received
Monitoring Events
The
events
command has one optional parameter. The format is:
events [clear]
where:
clear
- clears the event log. (You can only do this with the “admin” login.)
RMON Logged Events Summary
Entry
Time
Description
1
0 hrs 26 mins
Rising threshold alarm for etherStatsOctets on slot 2 port 1
2
0 hrs 27 mins
Rising threshold alarm for etherStatsOctets on slot 2 port 1