Alcatel Carrier Internetworking Solutions Omni Switch/Router User Manual
Page 348

Trap Tables
Page 13-28
Trap Type
moduleChange
Object ID
1.3.6.1.4.1.800.3.1.1.4.0.2
Description
A module was either inserted or removed from the chassis. In some
cases, this trap may also be generated when a module is reset.
Bit Position
(Word 1)
1
Hex Value
(Word 1)
2
Trap Text
and
Variable
Descrip-
tions
Module was inserted or removed from chassis (slot 4, subunit 1, type 10)
Slot Number
. The slot number on
the front of the chassis where this
module was inserted or removed.
Submodule Type
. Indicates the submodule that was
inserted or removed. Typically this value will be 1,
meaning the base module was inserted or removed.
If this value is 2, then HSX module 1 was moved. If
this value is 3, then HSX module 2 was moved.
4 HSM
5 MPM
6
ESM 8-port 10BASE-T
7
ESM 16-port
8
TSM 6-port UTP/STP
9
FSM FDDI module
10
FSM CDDI module
11
ESM 4-port
12
ASM .5 MB multi-mode
13
ESM 12-port 10BASE-T
14
ESM 6-port universal module
15
MPM version II
16
ATM DS-3
17
FSM FDDI single mode
18
ASM .5 MB single mode
19
ASM UTP
20
ESM 8-port fiber
Module Type
. Indicates the module type that was inserted
or removed. The following integers are valid values:
21
ESM 12-port Telco
22
TSM fiber
23
ASM 2 MB multi-mode
24
ASM 2 MB single mode
25
WSM
26
WSM BRI
27
HSM2 base slot type
28
PizzaSwitch reserved
29
TSM CD-6
30
ASM 2 MB single mode
33
10Meg Ether Universal
34
ATM E3 (European)
35
Ether 100 FX Sngl Full Dup
36
Ether 100 FX Multi Full Dup
37
Ether 100 TX CU Full Dup
39
PizzaPort (repeater)