Alcatel Carrier Internetworking Solutions Omni Switch/Router User Manual
Page 1059
![background image](/manuals/39732/1059/background.png)
Running Diagnostics on an Entire Chassis
Page 36-21
2) Stop on Failure
Enter
2
to halt diagnostics in an active state when a failure occurs or
1
(the default) to exit
diagnostics and display the
Test Summation
and
Failure Summation
sections of the
test
command output. Setting this field to
2
can be used to further troubleshoot problems.
However, setting this field to
2
requires more user intervention during a test.
3) Port Test Bypass
Enter
2
to complete testing of all ports regardless of port test failures or
1
(the default) to stop
testing at the first port failure. Setting this field to
2
can be used to further troubleshoot prob-
lems.
4) Port Test Type
Enter
1
(the default) for a port test,
2
for an Internal Loopback (
ILB
) test,
3
for a stress test, or
4
for an
ILB
stress test. External cables are required for the port and stress tests but not for the
ILB
test. In addition, the stress test requires a special image file (see Running Diagnostics on
page 36-2) and is only available for Ethernet (
ESX
and
GSX
) modules on the Omni
Switch/Router.
♦ Note ♦
Option 5,
HRE-X Test Mode
, is for the Omni
Switch/Router only.
5) HRE-X Test Mode
This option lets you configure port tests for
HRE-Xs
installed on Omni Switch/Router switch-
ing modules. It does not affect the port test for
HRE-Xs
installed on
MPXs
. Currently, the port
test on
HRE-Xs
installed on switching modules runs in conjunction with the normal port test.
Each physical port is tested with the normal port test path and then through the
HRE-X
port
test path before testing the next physical port. Subsequent physical ports are tested with only
the normal port test path.
Enter
1
to bypass testing of the
HRE-X
when the port test is run or
2
to perform the test as
described above.