Running Diagnostics on an Entire Chassis
Page 36-20
Running Diagnostics on an Entire Chassis
The
testcfg
command allows you to tailor diagnostic testing characteristics by module or for
an entire chassis. (Please refer to Configuring the Diagnostic Test Environment on page 36-16
for configuring tests for a single module.)
For example, to configure diagnostic tests for an entire chassis, enter:
testcfg all
A screen similar to the following will be displayed.
Test Configuration
1) Diagnostic Mode
{ Normal
(1),
Diagnostic
(2) } : Normal
2) Stop on Failure
{ Disable
(1),
Enable
(2) } : Disable
3) Port Test Bypass
{ Disable
(1),
Enable
(2) } : Disable
4) Port Test Type
{ Port
(1),
ILB
(2),
STRESS
(3),
ILBSTRESS
(4) } : Port
5) HRE-X Test Mode
{ Do not test HRE-X
(1),
Test HRE-X
(2) } : Test HRE-X
Enter (option=value/save/cancel)
:
Select the number of the item you want to change. To change any of the values listed above,
enter the line number, followed by an equal sign, and then the new value. For example, to
change the port test type to
STRESS
, enter:
4=3
To update the values you have changed, enter
save
. If you do not want to save the changes
enter
quit
or
cancel
, or press
Ctrl-D
. If you enter
save
, the change will be made and the
following message will be displayed.
Configuration Saved
If you cancel the
testcfg
command, it will terminate and the following will be displayed.
Exiting menu - Test Configuration not modified
The fields displayed by the
testcfg
command with the
all
option are described below.
1) Diagnostic Mode
Enter
1
(the default) to set to normal diagnostics testing or
2
for a more detailed version of
diagnostic testing. However, setting this field to
2
requires more user intervention during a
test.