Configuring 802.1q on gigabit ethernet ports, Configuring 802.1q on gigabit ethernet ports -11 – Alcatel Carrier Internetworking Solutions Omni Switch/Router User Manual
Page 441
![background image](/manuals/39732/441/background.png)
Assigning an 802.1Q Group to a Port
Page 16-11
Configuring 802.1Q on Gigabit Ethernet Ports
Use the
cas
command to assign
802.1Q
groups to Gigabit ports. To use this command, follow
the steps below.
1. Enter
cas
at the system prompt, as shown:
cas
where
is the slot of the module, and
is the port number that is to be added
to the group. For example, to add port 3 on slot 5, you would enter:
cas 5/3
2. If you have a Kodiak Gigabit module, the following prompt displays:
Slot 3 Port 5 Ethernet 802.1Q Service
1. Description (30 chars max)
:
2. Group ID
: 0
3. Tag
: 0
4. Priority Remap Values
:
40. 0 - 0
41. 1 - 1
42. 2 - 2
43. 3 - 3
44. 4 - 4
45. 5 - 5
46. 6 - 6
47. 7 - 7
You can modify the parameters by entering the line number, an equal sign, and the value
for the parameter. For example, to change the
Group ID
to
5
, you would enter
2
(the line
number for
Group ID
), an equal sign (
=
), and a
5
(the group number), as shown:
2=5
3. Remember to save your changes by typing
save
at the system prompt when you have
finished with the configuration.
Most of the fields are the same as described in Configuring 802.1Q on 10/100 Ethernet Ports
on page 16-8.