Error Messages
Page 35-12
Serial Port Configuration Errors
Message
Corrective Action
Problem deleting SLP port
xxx
, errno=
xx
Reboot the system, then use the Boot Line configuration to
force SLIP down at the boot line (refer to Appendix A “The
Boot Line Prompt”).
Can’t modify SLIP if it’s not
up! current mode=
xxx
Reconnect the SLIP line; reconfigure using the
slipc
command.
Problem
changing
SLIP
remote IP addr to
xxx
Check the remote IP address by using the
slipc
command at
the UI. Refer to Chapter 6, “Configuring Management Processor
Modules.”
Couldn’t setup SLIP port sl
xxx
on
xxx
Reboot the switch.
Module Connection Errors
Message
Corrective Action
interrupt: Link Error Monitor
ALERT on
xxx
/
xxx
PHY-
xxx
If this message shows up once or twice, it probably means that
someone is plugging a new cable in slot/port xxx/xxx, physical
connector xxx. If it displays more frequently, then there is
probably a bad CDDI or FFDI connection on slot/port xxx/xxx,
physical connector xxx, caused by either dirty connectors or
bad cabling. Try cleaning the connections or replacing the