Replacing Power Supplies (9-Slot Chassis)
Page 1-30
Replacing Power Supplies (9-Slot Chassis)
If a power supply ever needs to be replaced in an Omni Switch/Router 9-slot Chassis (e.g.,
OmniS/R-9 or OmniS/R-9p), it is strongly recommended that power supplies not be mixed,
except under the conditions and exceptions shown in the following table.
♦ Note ♦
In all cases, swapping operations must be made with
the power switch of the replacement power supply
turned OFF. Failure to turn the power switch off during
the swapping operation may cause the data switch to
reset and restart.
Replacing Power Supplies (9-Slot Chassis)
If One of Two
Power Supplies
Fails
Revision
Replace
With
650-watt
Pre-M1
Both
Power
Supplies
Two 650-watt (Revision M1+)
or two 725-watt Power
Supplies
650-watt
M1 or later
Failed
Power
Supply
One 650-watt (Revision M1+)
or one 725-watt Power
Supply
725-watt
Any
Failed
Power
Supply
One 725-watt Power Supply