Trap Tables
Page 13-63
Trap Type
fddiLerFlagChange
Object ID
1.3.6.1.4.1.800.3.1.1.1.0.65
Description
The
LER
(Link Error Rate) flag on a port changed from
CLEAR
to
SET
.
Bit Position
(Word 3)
0
Hex Value
(Word 3)
1
Trap Text
and
Variable
Descrip-
tions
FDDI: Link Error Rate on a port is set (SMTIndex 1, port 2, LerFlag 3)
LER Flag
. The condition becomes
a c t i v e w h e n t h e v a l u e o f t h e
fddiPRTLerEstimate is less than or
equal to fddimibPORTLerEstimate.
The following integers are valid
values:
1
True
2
False
SMT Index
. A unique value for
each SMT (Station Management).
The value for each SMT must
remain constant at least from
one re-initialization of the enti-
ty’s network management sys-
tem to the next re-initialization.
Port index
. A unique value for each port
with in a given SMT, which is the same
as the corresponding resource index in
SMT. The value for each port must
remain constant at least from one re-ini-
tialization of the entity’s network man-
a g e m e n t s y s t e m t o t h e n e x t r e -
initialization.