Yaskawa Sigma II Series Servo System User Manual
Page 466

Sigma II User’s Manual
Appendix B: List of Parameters
B - 26
*1 Whether it is resettable after the cause of the alarm condition is removed, or whether
power cycling is necessary in order to reset the device.
A. b3
×
×
×
×
Current
detection error
For 1kW or smaller
models. Amplifier
stays in BB for 500ms
after servo ON signal
input and brake
release with the servo
in a ready state.
resettable
Check the
wiring in motor
power line.
Replace the
servo
amplifier.
A.F5
×
×
×
Motor
disconnection
alarm
The detected torque
is 10% or less, but the
commanded torque
reference is 90% or
more for 10ms. This
alarm is not activated
in cases of BB due to
hardware issues. In
those cases, an A.F6
or A.b3 is generated
instead.
resettable
Check the
wiring in motor
power line.
Replace the
servo
amplifier.
Warning List
Warning
Warning Code Output
Warning
Name
Warning Occurring Cause
Solution
ALO1
ALO2
ALO3
A.90
×
×
×
Excessive
Position Error
Warning
Position error exceeds
Pn51E.
If a position error
is within Pn51E, it
automatically
reset.
Alarm list
Alarm
Alarm Code Output
Servo
Alarm
Output
Alarm Name
Alarm Occurrence
Cause
Alarm
Reset
*1
Solution
ALO1
ALO2
ALO3
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)