6 operation in parameter setting mode, 6 operation in parameter setting mode - 8, Operation in parameter setting mode -8 – Yaskawa Sigma II Series Servo System User Manual
Page 282

Sigma II User’s Manual
Chapter 7: Using the Digital Operator
7 - 8
7.1.6
Operation in Parameter Setting Mode
Functions can be selected or adjusted by setting parameters. There are two types of
parameters that can be set. One type requires value setting and the other requires
function selection. These two types use different setting methods.
•
With value setting, a parameter is set to a value within the specified range of the
parameter.
•
With function selection, the functions allocated to each digit of the
seven-segment LED panel indicator (five digits) can be selected.
See Appendix B List of Parameters.
Changing Parameter Settings
The parameter settings can be used to change parameter data. Check the permitted
range of the parameters in Appendix B List of Parameters, before changing the data.
The example below shows how to change parameter Pn507 from 100 to 85.
Using the Hand-held Digital Operator
1.
Press the DSPL/SET key to select the parameter setting mode.
2.
Select the parameter number to set. (Pn507 is selected in this example.)
Press the Left Arrow or Right Arrow key to select the digit. The
selected digit will flash.
Press tthe Up Arrow or Down Arrow key to change the value.
3.
Press the DATA/ENTER key to display the current data for the parameter
selected at step 2.
4.
Change the data as needed (to 85, in this example).
Press the Left Arrow or Right Arrow key to select the digit. The selected
digit will flash.
Press the Up Arrow or Down Arrow key to change the value.
Continue pressing the key until “00085” is displayed.