beautypg.com

A.30, Display and outputs, Status and remedy for alarm – Yaskawa Sigma II Series Servo System User Manual

Page 397

background image

Sigma II User’s Manual

Chapter 9: Inspection, Maintenance, and Troubleshooting

9 - 9

A.30

A.30: Regenerative Error Detected

Display and Outputs

Note:

OFF:

Output transistor is OFF (alarm state).

ON:

Output transistor is ON.

Status and Remedy for Alarm

Alarm Outputs

Alarm Code Output

ALM Output

ALO1

ALO2

ALO3

ON

ON

OFF

OFF

Cause of the Problem

Solution

A

Malfunctioning regenerative transistor.

Replace servo amplifier.

B

Regenerative resistor is open.

Replace servo amplifier or regen-

erative resistor.

C

Disconnected regenerative unit

(for an external regenerative resistor).

Check the wiring of the external

regenerative resistor.

D

Defective servo amplifier.

Replace servo amplifier.

When the control power

About 1s after main circuit

During servomotor

operation.

is turned ON.

A, B

A, B, C

D

power is turned ON.