Chapter 7: Using the Digital Operator

7 - 44

7.2.10 Manual Zero Adjustment and Gain Adjustment of

Analog Monitor Output

Motor speed, torque reference, and position error can be monitored through the

analog monitor output. Refer to 6.5 Analog Monitor.
Use the manual zero adjustment function to compensate for the output voltage drift
or the zero point drift caused by noise entering the monitor system. The gain

adjustment function can be changed to match the sensitivity of the measuring

system.

Note: The output voltage of the analog monitor is ±8V. The output voltage polarity will be reversed if ±8V

is exceeded.

Monitor Output Voltage

Zero Adjustment

Gain Adjustment

Setting Unit

Zero Setting Range: ±2V 17mV/LSB

Gain Setting Range: 50 to 150% 0.4%/LSB