Yaskawa Sigma II Series Servo System User Manual
Page 218

Sigma II User’s Manual
Chapter 5: Parameter Settings and Functions
5-132
Speed Related Parameters When a Direct-drive Motor is Connected
As the maximum speed of SGMCS servomotor is approximately 1/10 of standard
SGM H servomotor, the unit of parameter setting is changed to 1/10 of the
standard.
When a SGMCS servomotor is connected, the SERVOPACK changes the setting
unit automatically as shown in the following table.
Also, when a motor with a maximum speed is 500 rpm or less is connected, the
SERVOPACK changes the setting unit to 1/10 of the standard automatically.
Besides the parameter, the speed setting for the auxiliary function Fn003 "Zero-point
search mode" is fixed to 6 [rpm] when a direct-drive servomotor is connected.
Also, the analog monitor output units are changed as shown in the shaded areas in the
table below.
Parameters
No.
Name
Units
Setting
Range
Factory
Setting
Direct Drive servomotor
or servomotor whose maximum
speed is 500 rpm or less
Others
Pn301
Speed 1
0.1 rpm
rpm
0 to 10000
100
Pn302
Speed 2
0.1 rpm
rpm
0 to 10000
200
Pn303
Speed 3
0.1 rpm
rpm
0 to 10000
300
Pn304
JOG
Speed
0.1 rpm
rpm
0 to 10000
500
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 USB Copy Unit (2 pages)
- JVOP-181 (22 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)