7.1.3
Resetting Servo Alarms
Servo alarms can be reset using the digital operator.
Using the Hand-held Digital Operator
Press the RESET key in status display mode.
Using the Built-in Panel Operator
Press the Up Arrow AND Down Arrow keys together in status display mode.
The alarm can be reset with CN1-44, or /ALM-RST signal input. Refer to 5.5.1
Using Servo Alarm and Alarm Code Outputs.
The servo alarm will be reset if the control power supply is turned OFF.
• If an alarm is ON, reset the alarm after eliminating the cause of the alarm first. Refer to 9.2 Troubleshooting.
SGDM-
MODE/SET DATA/
SERVOPACK
200V
YASKAWA
Built-in Panel Operator
Key
Name
Function
Up Arrow
Key
• Press this key to set parame-
ters or display the set values of
parameters.
• Press the Up Arrow key to
increase the set value.
• Press the Down Arrow key to
decrease the set value.
• Press the Up and Down Arrow
keys together to reset a servo
alarm.
Down Arrow
Key
MODE/SET
Key
Press this key to select the status
indicator mode, auxiliary function
mode, parameter setting mode, or
monitor mode.
DATA/SHIFT
Key
• Press this key to set each
parameter or display the set
value of each parameter.
• This key is used for selecting
the editing (flashing) digit or
data setting.
MODE/SET
DATA/
IMPORTANT