Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5-126

5.8.6

Reactor for Harmonic Suppression

SGDH servo amplifiers have DC reactor connection terminals for power supply

harmonic suppression.

Connecting a DC Reactor

The DC reactor is connected in series to the rectifier circuit’s output side. Refer to
3.2 Servo Amplifier Internal Block Diagrams.

At the time of shipping, the servo amplifier’s (+)1 and (+)2 are short-circuited.
Remove the lead wire between the two terminals and connect the DC reactor.

Servo amplifier

DC reactor

⊕1