B.5 auxiliary functions – Yaskawa Sigma II Series Servo System User Manual
Page 457

Sigma II User’s Manual
Appendix B: List of Parameters
B - 17
B.5 Auxiliary Functions
The following list shows the available auxiliary functions.
Parameter
Function
Fn000
Alarm traceback data display.
Fn001
Rigidity setting for online autotuning.
Fn002
JOG mode operation.
Fn003
Zero-point search mode.
Fn004
(Reserved parameter).
Fn005
Parameter settings initialization.
Fn006
Alarm traceback data clear.
Fn007
Writing to EEPROM inertia ratio data obtained from online autotuning.
Fn008
Absolute encoder multi-turn reset and encoder alarm reset.
Fn009
Automatic tuning of analog (speed, torque) reference offset.
Fn00A
Manual adjustment of speed reference offset.
Fn00B
Manual adjustment of torque reference offset.
Fn00C
Manual zero-adjustment of analog monitor output.
Fn00D
Manual adjustment of analog monitor output gain.
Fn00E
Automatic adjustment of motor current detection signal offset.
Fn00F
Manual adjustment of motor current detection signal offset.
Fn010
Write protect setting (protects parameters from being changed).
Fn011
Motor model display. (
)
Fn012
Software version display.
Fn013
Multi-Turn Limit Setting: Change when a Multi-Turn Limit Disagreement Alarm (A.CC) occurs.
Fn014
Clear Option Unit Detection Alarm (A.E7).