Yaskawa Sigma II Series Servo System User Manual
Page 443

Sigma II User’s Manual
Appendix B: List of Parameters
B - 3
Gain P
a
rameters
Pn118
Reserved parameters (Do not
change).
%
20 to 100
100
—
Pn119
s
-1
1 to 2000
50
—
Pn11A
0.1%
1 to 2000
1000
—
Pn11B
Hz
1 to 150
50
—
Pn11C
Hz
1 to 150
70
—
Pn11D
%
1 to 150
100
—
Pn11E
%
1 to 150
100
—
Pn11F
ms
1 to 2000
0
—
Pn120
0.01ms
1 to 51200
0
—
Pn121
Hz
10 to 250
50
—
Pn122
Hz
0 to 250
0
—
Pn123
%
0 to100
0
—
Position
Parameters
*
Position Control Reference Selection
Switches
—
—
0000
5.2.2
*
PG Divider
p/r
16 to
16384
16384
5.2.3
*
Electronic Gear Ratio (Numerator)
—
1 to 65535
4
5.2.5
*
Electronic Gear Ratio (Denominator)
(See note 3).
—
1 to 65535
1
5.2.5
Pn204
Position Reference Accel/Decel
Parameter
0.01ms
0 to 6400
0
6.1.2
*
Multi-Turn Limit Setting
**
rev
0 to 65535
65535
5.7.2
Pn206
Reserved parameter (Do not change).
P/rev
513 to
65535
16384
—
*
Position Control Function Switches*
—
—
0000
5.2.9
6.1.2
*
Position Reference Movement
Averaging Time
0.01ms
6 to 6400
0
6.1.2
Speed
Pa
ra
me
te
rs
Pn300
Speed Reference Input Gain
0.01V/ rated
speed
150 to
3000
600
5.2.1
Pn301
Speed 1
rpm
0 to 10000
100
5.2.6
Pn302
Speed 2
rpm
0 to 10000
200
5.2.6
Pn303
Speed 3
rpm
0 to 10000
300
5.2.6
Pn304
Jog Speed
rpm
0 to 10000
500
5.3.2
Pn305
Soft Start Acceleration Time
ms
0 to 10000
0
6.1.1
Pn306
Soft Start Deceleration Time
ms
0 to 10000
0
6.1.1
Pn307
Speed Reference Filter Time
Constant
0.01ms
0 to 65535
40
—
Pn308
Speed Feedback Filter Time Constant
0.01ms
0 to 65535
0
6.2.6
Torque Parameters
Pn400
Torque Reference Input Gain
0.1V/rated
torque
10 to 100
30
5.2.7
Pn401
Torque Reference Filter Time
Constant
0.01ms
0 to 65535
100
6.1.5
Pn402
Forward Torque Limit
%
0 to 800
800
5.1.3
Pn403
Reverse Torque Limit
%
0 to 800
800
5.1.3
Pn404
Forward External Torque Limit
%
0 to 800
100
5.1.3
Pn405
Reverse External Torque Limit
%
0 to 800
100
5.1.3
Pn406
Emergency Stop Torque
%
0 to 800
800
5.1.2
Pn407
Speed Limit during Torque Control
rpm
0 to 10000
10000
5.2.7
Pn408
Torque Function Switches
—
—
0000
6.1.6
Pn409
Notch Filter Frequency
Hz
50 to 2000
2000
6.1.6
Cat.
Parameter
Number
Name
Unit
Setting
Range
Default
Setting
Reference