Allocating other output signals – Yaskawa Sigma II Series Servo System User Manual

Page 144

background image

Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5-58

Allocating Other Output Signals

Note: Signals are output with OR logic when multiple signals are allocated to the same output circuit.

Signals that are not detected are invalid. For example, the positioning completed signal /COIN is
invalid in Speed Control Mode.

The following parameters can be used to invert the signals on output terminals SO1
to SO3.

These settings specify which of the connector CN1 output signals are to be inverted:

Output Signal

Parameter

Description

Number

Setting

Positioning Completed

(/COIN)

Pn50E.0

0

Disabled. (Not used for the specified output

signal.)

1

Outputs the specified signal from the SO1

(CN1-25 and 26) output terminal.

2

Outputs the specified signal from the SO2

(CN1-27 and 28) output terminal.

3

Outputs the specified signal from the SO3

(CN1-29 and 30) output terminal.

Speed Coincidence

Detection

(/V-CMP)

Pn50E.1

0 to 3

Same as above (

Output signals are disabled or

allocated to output terminals SO1 to SO3

through parameter settings 0 to 3).

Rotation Detection

(/TGON)

Pn50E.2

0 to 3

Servo Ready

(/S-RDY)

Pn50E.3

0 to 3

Torque Limit Detection

(/CLT)

Pn50F.0

0 to 3

Speed Limit Detection

(/VLT)

Pn50F.1

0 to 3

Brake Interlock

(/BK)

Pn50F.2

0 to 3

Warning

(/WARN)

Pn50F.3

0 to 3

Near

(/NEAR)

Pn510.0

0 to 3

Not used

Parameter

Signal

Setting

Description

Pn512

Output Signal Inverted Setting

Default Setting: 0000

Speed/Torque Control,

Position Control

Output Terminal

Parameter

Description

Number

Setting

SO1

(CN1-25, 26)

Pn512.0

0

Does not invert the signal.

1

Inverts the signal.