7 - 45
Manual Zero Adjustment of Analog Monitor Output
Follow the procedure below to execute the manual zero adjustment of analog
monitor output.
Using the Hand-held Digital Operator
1.
Press the DSPL/SET key to select the auxiliary function mode.
2.
Select the parameter Fn00C.
Press the Left Arrow or Right Arrow key to select the digit.
Press the Up Arrow or Down Arrow key to change the value.
3.
Press the DATA/ENTER key, and the display will be as shown below.
4.
Press the DSPL/SET key. Each time the MODE/SET key is pressed, the
monitor output will toggle between the displays for the two channels shown
below.
5.
Press the Left Arrow or Right Arrow key to display the analog monitor
output data. Pressing the Left Arrow or Right Arrow key again will
return to the display shown in the above step 3 or 4.
6.
Press the Up Arrow or Down Arrow key to perform zero adjustment of the
analog monitor output.
7.
When zero adjustment has been completed for the two channels, press the
DATA/ENTER
key to return to the auxiliary function mode display.
DSPL/SET Key
Displayed
alternately
Data Display
Displayed
alternately
LEFT Cursor Key
(RIGHT Cursor Key) Data Display
Data Setting Change