Parameter
Content of Display
Unit
Remarks
Un000
Actual motor speed
rpm
—
Un001
Input speed reference
rpm
—
Un002
Internal torque reference
%
Value for rated torque
Un003
Rotation angle 1
pulse
Number of pulses from the origin
Un004
Rotation angle 2
degree
Angle from the origin (electrical angle)
Un005
Input signal monitor
—
—
Un006
Output signal monitor
—
—
Un007
Input reference pulse speed
rpm
—
Un008
Error counter value
reference units
Amount of position error
Un009
Accumulated load rate
%
Value for the rated torque
Displays in 10s cycle.
Un010
Allowable maximum motor speed/
dividing ratio
100 mm/s or
Pulse/scale
pitch
(
Pn280)
Displays in decimal codes.
Un011
Hall sensor signals
–
–
Un00A
Regenerative load rate
%
Value for the processable regenerative
power
Displays in 10s cycle.
Un00B
Power consumed by DB resistance
%
Value for the processable power when
dynamic brake is applied
Displays in 10s cycle.
Un00C
Input reference pulse counter
—
Displayed in hexadecimal.
Un00D
Feedback pulse counter
—
Displayed in hexadecimal.
Un100~
UN104