Manual gain adjustment of analog monitor output, Using the hand-held digital operator – Yaskawa Sigma II Series Servo System User Manual
Page 321

Sigma II User’s Manual
Chapter 7: Using the Digital Operator
7 - 47
Manual Gain Adjustment of Analog Monitor Output
Follow the procedure below to execute the manual gain adjustment of analog
monitor output.
Using the Hand-held Digital Operator
1.
Press the DSPL/SET key to select the auxiliary function mode.
2.
Select the parameter Fn00D.
Press the Left Arrow or Right Arrow key to select the digit.
Press the Up Arrow or Down Arrow key to change the value.
3.
Press the DATA/SHIFT key, and the display will be as shown below.
4.
Press the DSPL/SET key. Each time the DSPL/SET key is pressed, the monitor
output will toggle between the displays for the two channels shown below.
5.
Press the Left Arrow or Right Arrow key to display the analog monitor
gain parameter. Pressing the Left Arrow or Right Arrow key again will
return to the display shown above in step 3 or 4.
6.
Press the Up Arrow or Down Arrow key to adjust the gain for the analog
monitor output.
7.
When the gain adjustment has been completed for the two channels, press the
DATA/ENTER
key to return to the auxiliary function mode display.
This completes the manual gain adjustment of the analog monitor output.
DSPL/SET Key
Displayed
Alternately
Left Cursor Key
(Right Cursor Key)
Data Display
Displayed
Alternately
Data Setting Change