Yaskawa Sigma II Series Servo System User Manual
Page 363

Sigma II User’s Manual
Chapter 8: Ratings and Characteristics
8 - 33
Specifications for Servo Amplifier and Single-phase, 100V
Servomotor Combinations
*1
Input current rates are at the lower range of the voltage specifications.
*2
Allowable regenerative energy is the value with an AC input power supply voltage of 200V
rms
.
This may vary with power supply fluctuation.
Note:
Refer to 5.6 Selecting a Regenerative Resistor for more details on allowable regenerative energy
and frequency.
Voltage
Single-phase 100V
Servo Amplifier Model
SGDH-
A3BE
A5BE
01BE
02BE
SGMA
H Ser
ies
Ap
pli
cab
le
Se
rvom
otor
Model
SGMAH-
A3B
A5B
01B
02B
Capacity
(kW)
0.03
0.05
0.1
0.2
Motor Speed
(rpm)
Rated 3000/maximum 5000
Applicable Encoder
Standard: 13-bit incremental encoder
Continuous Input Current
*1
A
rms
1.1
1.8
3.0
5.2
Continuous Output Current
A
rms
0.66
0.95
2.4
3.0
Maximum Output Current
A
rms
2.0
2.9
7.2
9.0
Allowable Regenerative Energy
*2
(Joules)
7.8
15.7
Voltage
Single-phase 100V
Servo Amplifier Model
SGDH-
A3BE
A5BE
01BE
02BE
SGMPH Series
Appli
cab
le
Se
rvom
otor
Model
SGMPH-
—
—
01B
02B
Capacity
(kW)
—
—
0.1
0.2
Motor Speed
(rpm)
Rated 3000/maximum 5000
Applicable Encoder
Standard: 13-bit incremental encoder
Continuous Output Current
A
rms
—
—
2.2
2.7
Maximum Output Current
A
rms
—
—
7.1
8.4
Allowable Regenerative Energy
*2
(Joules)
—
15.7