Initializing Parameter Settings

This function is used to restore all the parameters to the default settings (standard
factory settings).

Follow the procedure below to initialize parameter settings.

Using the Hand-held Digital Operator

1.

Press the DSPL/SET key to select the auxiliary function mode.

2.

Select the parameter Fn005.

Press the Left Arrow or Right Arrow key to select the digit.

Press the Up Arrow or Down Arrow key to change the value.

3.

Press the DATA/ENTER key, and the display will be as shown below.

4.

Press the DSPL/SET key, and the display will be as shown below. The

parameters will be initialized.

5.

Press the DATA/ENTER key to return to the auxiliary function mode display.

This completes the initialization of parameter settings.

• Initialize the parameter settings with the servo OFF.
• After performing the procedure, cycle the power to restore all the parameters to the default settings.

IMPORTANT

Flashing for

one second

Flashing during

initialization

End