Pulse-on duration and pulse-off duration

The pulse-on duration (TON) is the time in which the generator
applies a voltage to the electrode and workpiece.
Ignition and subsequent discharge take place during this time.

The pulse-off duration (TOF) is the time in which no voltage is
generated.
During this time the gap is flushed and deionized.

Select the TON/TOF ratio according to the type of machining:

Setting

„

Roughing: Long pulse-on duration, short pulse-off duration

„

Finishing and polishing: Short pulse-on duration, long pulse-off
duration

Servo sensitivity SV

The servo sensitivity influences the reaction speed of the gap control.

Setting

„

High servo sensitivity: fast gap control

„

Low servo sensitivity: slow gap control

Input range

0 to 99 %

Erosion time ET, Auto jump distance AJD

The erosion time determines how long an erosion step lasts. When
the programmed erosion time has run out, the electrode retracts by
the auto jump distance and subsequently returns to the position
given in machine parameter MP2051.

Intermittent flushing

To improve deionization of the gap and flush away debris, you can
activate miscellaneous function M8 (intermittent flushing ON).

U gap

F

SV= 99

SV= 60

2

t

U

T- ON

TF

1

t

U

T- ON

TF

ET

AJD

ET

AJD

MP 2051

The machine tool builder specifies a characteristic curve
for servo sensitivity (see figure center right). Refer to your
machine tool manual.