4 er osion cy cles – HEIDENHAIN TNC 406 User Manual
Page 159
138
8 Programming: Cycles
8.4 Er
osion Cy
cles
Contouring program PGM
The cycle parameter PGM determines the contouring program that is
to be used by the TNC.
Sparking-out distance in percent PRC
This parameter determines how far the TNC should retract for
sparking-out after having reached the eroding depth. The value is to be
entered as a percentage of the total contour length.
Requirements for the contouring program:
The contour programmed in the contouring program
must be a closed contour, such as a rectangle.
The start of the contour should be in the middle, so that
the contour is scalable with Cycle 11.
No coordinates may be programmed for the eroding axis
in the contouring program. The eroding axis and eroding
depth are specified in Cycle 14.
No M functions that cause a geometry reset, such as
M02 or M30, may be programmed in the contouring
program.