6 checking and changing q parameters, Procedure – HEIDENHAIN TNC 406 User Manual
Page 217

196
10 Programming: Q Parameters
1
0
.6 Chec
king and Changing Q P
a
ra
met
e
rs
10.6 Checking and Changing
Q Parameters
Procedure
Q parameters can be checked during a program run or test run. If you
wish to change any Q parameters, you must interrupt the program run
or test run.
Select the supplementary operating mode MOD.
Press the Q parameter status soft-key: The TNC
shows a list of the first 15 parameters.
To scroll through the subsequent Q parameters, press and hold the
down arrow key. You can go to a specific Q parameter by pressing the
GOTO key and entering the desired Q parameter number.
You can only change the Q parameter if you have
interrupted the program run or test run. Enter the new
value, for example 0, and confirm with the ENT key.
Return to the last active operating mode.
0