beautypg.com

5 datum setting with a probing electrode, Functions for setting the datum, Writing probed values to tables – HEIDENHAIN TNC 406 User Manual

Page 49

background image

28

2 Manual Operation, Setup and Probing Functions

2.5 D

a

tu

m Set

ting with

a Pr

obing Electr

ode

2.5 Datum Setting with a

Probing Electrode

Functions for setting the datum

After probing you can set a new datum or transfer the captured values
to a datum or tool table.

Writing probed values to tables

The TNC writes the probed value to a table after the TRANSFER TO
TABLE soft key is pressed. You can choose a datum table (NAME.D)
as well as a tool table (NAME.T):

8

Select manual probing by pressing the TOUCH PROBE soft key.

8

Enter the name of the datum or tool table.

8

Enter the datum number or tool number.

8

Select the probing function and begin probing.

8

Press the TRANSFER TO TABLE soft key for the TNC to write the
probed value to the selected table.

Writing probed values to a table while a program is running

You can also write probed values to the TOOL table during program
run. Use miscellaneous function M109 to transfer the contents of the
Q parameters Q81 to Q84 into the table TOOL.T.
You can also use M108 to read the tool compensation values from the
TOOL table into parameters Q81 to Q84 (see also ”Q parameters for
the datum table: Q81 to Q84” on page 206).

Function

Soft key

Set the datum in any axis

Manual probing

Set the datum at a workpiece center

Set the datum at a circle center

Set the datum at a corner

In order to write probed values to datum tables, the tables
must be active on your TNC (bit 2 in machine parameter
7224 = 0).