beautypg.com

To enter erosion parameters in the erosion table, 7 p ar amet ers in the er osion t able – HEIDENHAIN TNC 406 User Manual

Page 84

background image

HEIDENHAIN TNC 406, TNC 416

63

4.7 P

ar

amet

ers in the Er

osion T

able

To enter erosion parameters in the erosion table

Activate file management.

Select a file with the arrow keys.

Enter the file name directly, e.g. 15. For a new erosion
table you must enter the name.

Open the selected erosion table.

Select program type .E (erosion table).

Enter the number of the power stage for the following
data. Confirm with ENT.

The TNC then asks for all further erosion parameters described in this
chapter.

To enter erosion parameters for additional power stages

With INSERT, erosion parameters for up to 25 power
stages can be entered.

To conclude entry

Return to program management with PGM NAME.

To go to a certain power stage

Use GOTO to directly access a certain power stage number in the
erosion table (do not enter the table row number).

Unit of measurement in the table

With the TAB soft key you can change the name of the table and the
unit of measurement. The same unit (millimeters or inches) should be
used in the erosion tables as in the NC program.

FILE NAME ?

PROGRAM SELECTION

POWER STAGE NUMBER

15

1