1 positioning with manual data input (mdi), Positioning with manual data input (mdi) – HEIDENHAIN TNC 406 User Manual
Page 59

38
3 Positioning with Manual Data Input (MDI)
3.1 P
o
sitioning with Manual D
ata Input (MDI)
3.1 Positioning with Manual Data
Input (MDI)
The POSITIONING WITH MANUAL DATA INPUT mode of operation is
particularly convenient for simple machining operations or exact pre-
positioning of the electrode. You can write a program in conversational
programming and execute it immediately. You can also define and call
TNC cycles. The program is stored in the file $MDI.
Positioning with manual data input (MDI)
Select the Positioning with MDI mode of operation.
Program the file $MDI as you wish.
To start program run, press the machine START button.
Example: Programming and processing a line
Select operating mode: Positioning with MDI.
Select the axis, and enter the end-point coordinates
of the line and the feed rate,
i.e.: L X+125 R F100 M
Conclude entry.
Start positioning block.
PGM CALL can not be used to call a program.
LBL CALL can not be used for calling sub-routines or
repeating sections of programs.
For a TOOL CALL block to processed, the
corresponding TOOL DEF tool definition must be
programmed within the $MDI file.
Incremental positionings always refers to the present
electrode position.
Programming a radius compensation (RL/RR) is not
permitted.