Baud rate for RS-422 interface of the PLC

MP5200
9600: 0
38400: 1

Check sequence of blocks with external data
transfer

MP5990
Check sequence of blocks with external data transfer: 0
No check: 1

Parameters for probing with the
TCH PROBE function

Number of times the probing process is
repeated for probing a workpiece

MP6100
0
to 5

Maximum difference between results from
probing a workpiece several times

The TNC aborts probing and generates an error
message if the difference between results
exceeds the value entered in MP6110.

MP6110
0
to 2 [mm]

Probe feed rate

MP6120
80
to 3 000 [mm/min]

Maximum traverse to first probe point

The TNC aborts probing and generates an error
message if the electrode does not reach the
workpiece within the defined measuring range.

MP6130
0
to 30 000 [mm]

Distance by which the electrode is retracted
when probing manually

If 0 is entered, the electrode is always retracted
to the starting point.

MP6140
0
to 30 000 [mm]

Retraction time after the end of electrode
contact when probing manually

MP6141
10
to 400 [ms]

Rapid traverse for probing

After probing, the TNC retracts the electrode at
the speed defined in this parameter.

MP6150
1
to 30 000 [mm/min]

TNC displays, TNC editor

Programming station

MP7210
TNC with machine: 0
TNC as programming station with active PLC: 1
TNC as programming station with inactive PLC: 2

External data transfer