1 gener a l user p ar amet ers – HEIDENHAIN TNC 406 User Manual
Page 270

HEIDENHAIN TNC 406, TNC 416
249
13.1 Gener
a
l User P
ar
amet
ers
Baud rate for RS-422 interface of the PLC
MP5200
9600: 0
38400: 1
Check sequence of blocks with external data
transfer
MP5990
Check sequence of blocks with external data transfer: 0
No check: 1
Parameters for probing with the
TCH PROBE function
Number of times the probing process is
repeated for probing a workpiece
MP6100
0 to 5
Maximum difference between results from
probing a workpiece several times
The TNC aborts probing and generates an error
message if the difference between results
exceeds the value entered in MP6110.
MP6110
0 to 2 [mm]
Probe feed rate
MP6120
80 to 3 000 [mm/min]
Maximum traverse to first probe point
The TNC aborts probing and generates an error
message if the electrode does not reach the
workpiece within the defined measuring range.
MP6130
0 to 30 000 [mm]
Distance by which the electrode is retracted
when probing manually
If 0 is entered, the electrode is always retracted
to the starting point.
MP6140
0 to 30 000 [mm]
Retraction time after the end of electrode
contact when probing manually
MP6141
10 to 400 [ms]
Rapid traverse for probing
After probing, the TNC retracts the electrode at
the speed defined in this parameter.
MP6150
1 to 30 000 [mm/min]
TNC displays, TNC editor
Programming station
MP7210
TNC with machine: 0
TNC as programming station with active PLC: 1
TNC as programming station with inactive PLC: 2
External data transfer