1 gener a l user p ar amet ers – HEIDENHAIN TNC 406 User Manual
Page 271

250
13 Tables and Overviews
13.1 Gener
a
l User P
ar
amet
ers
Disabling file types
MP7224 is bit-coded. If bit 2 is set, new tool
tables cannot be created. Existent tool tables
may still be edited, but the changes will be
ignored in program run.
MP7224
Not disabled: 0
File type disabled for
Bit 0 vacant
Bit 1 vacant
Bit 2 tool table: 4
All other bits are vacant
Dialog language
MP7230
Input value: 0 to 3
Languages for software 280620
English = 0
German = 1
French = 2
Italian = 3
Languages for software 280621
English = 0
German = 1
Swedish = 2
Finnish = 3
Languages for software 280622
English = 0
German = 1
Czech = 2
Reserved = 3
Protect OEM cycles in the TNC memory
MP7240
Protect OEM cycles: 0
Do not protect OEM cycles: 1
Inhibit EL-CALL and WP-CALL soft keys
MP7241
Do not display oft keys: 0
Display oft keys: 1
Number of pockets in the tool magazine
MP7261
0 to 999
Permit multiple assignment of pocket
numbers
Aside from pocket number 0, you can prevent a
pocket from being assigned more than once.
MP7265
Assign pocket number only once: 1
Assign pocket number several times: 0
Display feed rate
MP7271
Display feed rate F: 0
Do not display feed rate F: 1
TNC displays, TNC editor